Almacen PDF

Recopilación de libros en formatos PDF, EPUB y MOBI

Utilidad diagnóstica en el glaucoma del análisis de las fibras retinianas mediante polarimetría láser asociado a la autoperimetría y a sistemas de inteligencia artificial (redes neuronales)

Sinopsis del Libro

Libro Utilidad diagnóstica en el glaucoma del análisis de las fibras retinianas mediante polarimetría láser asociado a la autoperimetría y a sistemas de inteligencia artificial (redes neuronales)

Owing to the great importance of Glaucoma and because it is one of the main causes of blindness in the world, we are working to contribute a new help to obtain a diagnosis as early as possible, an adequate statistics and an early treatment for Glaucoma, so that we could improve the quality of life of persons who suffer this problem. The persons who have been included in the population sample were voluntarily included and they came from ophthalmic routine exams made in their practice, they signed the consent to be included in the protocol and they declared not taking any medication which could affect the results, in the same ways, they also declared not being regular drinkers or smokers. 106 eyes of 53 patients have been studied (31 women and 22 men) each eye was considered individually. The eyes are classified in different stages of Glaucoma, defined by an expert ophthalmologist, taking into account the definition proposed by Caprioli (1992), in which eyes are defined from group 0 (normal eyes) up to group 5 (terminal Glaucoma) from obtained data from the medical history (qualitative variable), from contributions of the visual area study by autoperimetry and from the study of nerve fiber layer of the retina by polarimetry laser (quantitative variable). The Artificial Intelligence is applicated, it is a neuronal network system which provide a degree of objectivity as much as possible when establishing a clinical diagnosis of Glaucoma. When we have finished the design and training of the system, the classification of the Artificial Intelligence will be able to assign each patient their corresponding group without the especialist taking part with a high index of specificity and sensitivity. Among the conclusions we underlined that the assessment of the visual memory by the program seven of the autoperimetry kinetic/static Dicon TKS 4000 is a fat and reliable test to differentiate healthy from pathological persons in advanced stages of Glaucoma without providing algorithms which can use to quantify the depth of the zone and their relation with incipient alterations. The functional capacity and measures of perimetric sensitivity quadrant are suitable parameters to be considered as input variables in neuronal network design in this study as evaluation of visual field defects by autoperimetry objectified. The analysis of retinal never fiber layer defects by scanning laser polarimetry using the GDX analyzer NFA II version, suppose an indirect quantitative method which objectifies peripapillary level changes. Among the index polarimetrics which we have obtained, we can use them as input variables of the neuronal net as follows: desviations from normal rates in each quadrant, the number of fibers and average thickness. The neuronal network multilayer perceptron of backpropagation shape in this study has the ideal caracteristics with 16 input neurons 30 hidden layer nodes and 1 neuron in the output layer requiring 8000 cycles with training features to achivie the minimum mistakes of the neural net. The neural network design achivies an efficiency of 100% in the discrimination and assignment to each stage of Glaucoma established by the specialist expert. Neuronal network integration proposed in this study, in the functional exploratory test and structural of affectation in the Glaucoma will allow to implement the ability to diagnosis and classification without high requeriments, there is no doubt that Neuronal network integration is an useful tool to interpret the results in terms of glaucomatous affectation, prognosis and therapeutic guidance.

Ficha Técnica del Libro

Número de páginas 364

Autor:

  • Inés Franco SuÁrez-bÁrcena

Categoría:

Formatos Disponibles:

MOBI, EPUB, PDF

¿Cómo descargar el libro?

Valoración

Popular

4.2

71 Valoraciones Totales


Más libros de la temática Medicina

Salud y prevención

Libro Salud y prevención

CAPÍTULO 1: LA DIETA MEDITERRÁNEA: EL ELIXIR DE LA ETERNA JUVENTUD. Ávalos López, Inmaculada; Martínez Pulgar, Nuria y Fernández Gil, Miguel Ángel. CAPÍTULO 2: RELACIÓN ENTRE DISFUNCIÓN OCUPACIONAL Y VOLICIÓN PARA EL DESEMPEÑO SALUDABLE DE OCIO. Castellano Ramírez, Julio; Contreras Parody, María Isabel y Hurtado Montiel, Mª Dolores. CAPÍTULO 3: FACTORES ASOCIADOS AL TABAQUISMO PASIVO EN NIÑOS Y ADOLESCENTES ASMÁTICOS EN UNA LOCALIDAD DE SANTIAGO DE CUBA. Dagnesses Fonseca, Javier Óscar. CAPÍTULO 4: BÚSQUEDA DE SALUD Y RELIGION. De la Poza Rodríguez, Mª Azahara; Portero...

PREM de Ginecología: capacitación para el ENARM

Libro PREM de Ginecología: capacitación para el ENARM

Resume los conceptos fundamentales de Ginecología y Obstetricia para quien busca consolidar sus conocimientos antes de presentar el Examen Nacional de Aspirantes a Residencias Médicas por lo que se convierte en un apoyo sólido para uno de los grandes escalones que el médico debe pasar para continuar con su formación profesional, razón por la cual, fue elaborado con la mejor intención de promover el estudio colaborativo de estos aspirantes.

Ciencia administrativa y gestión sanitaria

Libro Ciencia administrativa y gestión sanitaria

CAPÍTULO 1: DIABETES GESTACIONAL Y UTILIZACIÓN DE PROBIÓTICOS. Alayón Hernández, N.; González Pérez, I. y Terrón Barroso, J. CAPÍTULO 2: UN DIAGNÓSTICO ACERTADO. García Vílchez Blanca María; Muñoz Martínez María Jesús y Ruiz Padilla María Gema. CAPÍTULO 3: ACTUACIÓN DEL FISIOTERAPEUTA ANTE LAS ALTERACIONES DEL SISTEMA LINFÁTICO. Carrión Amorós, Yésica; Morales García, Mª Amparo y Rosa Ruiz, Silvia. CAPÍTULO 4: DESFIBRILADORES AUTOMÁTICOS. Marín Ramos, Marina; Fernández López, Isabel Mª y Simón Sánchez, Juana Esther. CAPÍTULO 5: NUTRICIÓN ENTERAL...

Evolución de la protección radiológica y control de calidad en la radiología dental española

Libro Evolución de la protección radiológica y control de calidad en la radiología dental española

Se estudian 7.176 informes oficiales de control de calidad de instalaciones de radiodiagnóstico dental pertenecientes a clínicas odontológicas que utilizan algún tipo de equipo de radiología intraoral. El estudio evolutivo corresponde a las cinco primeras revisiones de dichas instalaciones como consecuencia de la nueva normativa en la que se establecen las obligaciones que deben cumplir este tipo de instalaciones (1996-2001)

Libros Recomendados



Últimas Búsquedas


Categorías Destacadas